Precaution
1. Select capacitors according to voltage requirements and do not exceed specific voltage limits for the application.
2. Do not exceed the specified surge voltage (maximum overvoltage) of capacitors.
|
Explanatory Notes
1. Select capacitors with the correct rated voltage by following these guidelines:
(1) For capacitors with an AC voltage superimposed on a DC voltage, select
capacitors with a rated voltage that exceeds the total peak value of the
AC (ripple) voltage plus the DC voltage. If variable voltages are present, use the
highest peak value of the AC voltages plus the DC voltage to determine the
total operating voltage.
Highest Peak Value of Variable Voltages
(2) If using more than one capacitor connected in series, select a higher rated
voltage for the capacitors to compensate for the voltage imbalance caused by
differences in the leakage current of the capacitors. Also, equalize the voltage
imbalance by shunting external (balance) resistors across each capacitor.
Rated Voltage
of Capacitor
(3) If pulsing voltages are applied to a capacitor, select the capacitor with a rated
voltage higher than the pulsing voltages.
2. Surge voltage is the maximum overvoltage including DC, peak AC and transients to which capacitors may be subjected for short periods of time. This overvoltage causes a large amount of current to flow into a capacitor which generates internal gas, raises the vapor pressure and causes abnormal internal pressure. This pressure will cause the safety vent, if any, to rupture or damage the rubber seal causing electrolyte leakage. In extreme cases a capacitor may explode or catch on fire.
Although a surge voltage, which exceeds the rated voltage, is specified for capacitors in the Japanese Industrial Standard (JIS), it does not imply long-term use but limited use under specific conditions. See footnotes.
|
Footnotes:
The surge voltage (US), which exceeds the rated voltage
(UR) of capacitors, has been defined in the JIS as follows:
When UR 200 volts : US = UR @ 1.25
When UR > 200 volts : US = UR ~ 50 volts
For surge voltage tests, the above voltages (US) shall
be applied to the capacitors at a cycling rate of 30 seconds on,
5-1/2 minutes off, for 1,000 successive cycles at a specified temperature.